3 research outputs found

    Computational Fluid Dynamics (CFD) for blood flow in cardiovascular medical devices and blood damage prediction

    Get PDF
    Background: The hemodynamic performance of cardiovascular medical devices and their potential to cause blood damage are critical factors in ensuring patient safety and device efficacy. Computational Fluid Dynamics (CFD) has emerged as a valuable tool for simulating blood flow within these devices and predicting the risk of blood damage.Objective: This study aims to utilize CFD simulations to evaluate the local hemodynamic performance of a particular implantable device and to provide precise predictions about likely adverse clinical effects, cutting-edge techniques like LDA or PIV must be accessible.Methods: A patient-specific CFD model of the cardiovascular system and medical devices was developed based on medical imaging data. Hemodynamic parameters such as shear stress and flow recirculation were computed to identify regions of potential blood damage. The simulations were validated against data.Results: The CFD simulations revealed intricate flow patterns and areas of concern within the medical devices. Elevated shear stresses and prolonged residence times were identified in certain regions, indicating a risk of blood damage (Figure 2). By quantifying these parameters, the study provided a comprehensive assessment of potential blood damage locations and severity levels.Conclusion: Computational Fluid Dynamics proved to be a robust approach for evaluating blood flow within cardiovascular devices and predicting potential blood damage. The study highlighted specific design modifications that could mitigate the risk of blood damage, thus contributing to the improvement of device safety. The integration of CFD with patient-specific data offers clinicians and engineers a powerful tool for optimizing cardiovascular device design and minimizing patient risk

    Flow Dynamics in Cardiovascular Devices: A Comprehensive Review

    Get PDF
    This review explores flow dynamics in cardiovascular devices, focusing on fundamental fluid mechanics principles and normal blood flow patterns. It discusses the role of different structures in maintaining flow dynamics and the importance of stents, heart valves, artificial hearts, and ventricular assist devices in cardiovascular interventions. The review emphasizes the need for optimized designs and further research to enhance knowledge of flow dynamics in cardiovascular devices, advancing the field and improving patient care in cardiovascular interventions

    Mortality from gastrointestinal congenital anomalies at 264 hospitals in 74 low-income, middle-income, and high-income countries: a multicentre, international, prospective cohort study

    Get PDF
    Summary Background Congenital anomalies are the fifth leading cause of mortality in children younger than 5 years globally. Many gastrointestinal congenital anomalies are fatal without timely access to neonatal surgical care, but few studies have been done on these conditions in low-income and middle-income countries (LMICs). We compared outcomes of the seven most common gastrointestinal congenital anomalies in low-income, middle-income, and high-income countries globally, and identified factors associated with mortality. Methods We did a multicentre, international prospective cohort study of patients younger than 16 years, presenting to hospital for the first time with oesophageal atresia, congenital diaphragmatic hernia, intestinal atresia, gastroschisis, exomphalos, anorectal malformation, and Hirschsprung’s disease. Recruitment was of consecutive patients for a minimum of 1 month between October, 2018, and April, 2019. We collected data on patient demographics, clinical status, interventions, and outcomes using the REDCap platform. Patients were followed up for 30 days after primary intervention, or 30 days after admission if they did not receive an intervention. The primary outcome was all-cause, in-hospital mortality for all conditions combined and each condition individually, stratified by country income status. We did a complete case analysis. Findings We included 3849 patients with 3975 study conditions (560 with oesophageal atresia, 448 with congenital diaphragmatic hernia, 681 with intestinal atresia, 453 with gastroschisis, 325 with exomphalos, 991 with anorectal malformation, and 517 with Hirschsprung’s disease) from 264 hospitals (89 in high-income countries, 166 in middleincome countries, and nine in low-income countries) in 74 countries. Of the 3849 patients, 2231 (58·0%) were male. Median gestational age at birth was 38 weeks (IQR 36–39) and median bodyweight at presentation was 2·8 kg (2·3–3·3). Mortality among all patients was 37 (39·8%) of 93 in low-income countries, 583 (20·4%) of 2860 in middle-income countries, and 50 (5·6%) of 896 in high-income countries (p<0·0001 between all country income groups). Gastroschisis had the greatest difference in mortality between country income strata (nine [90·0%] of ten in lowincome countries, 97 [31·9%] of 304 in middle-income countries, and two [1·4%] of 139 in high-income countries; p≤0·0001 between all country income groups). Factors significantly associated with higher mortality for all patients combined included country income status (low-income vs high-income countries, risk ratio 2·78 [95% CI 1·88–4·11], p<0·0001; middle-income vs high-income countries, 2·11 [1·59–2·79], p<0·0001), sepsis at presentation (1·20 [1·04–1·40], p=0·016), higher American Society of Anesthesiologists (ASA) score at primary intervention (ASA 4–5 vs ASA 1–2, 1·82 [1·40–2·35], p<0·0001; ASA 3 vs ASA 1–2, 1·58, [1·30–1·92], p<0·0001]), surgical safety checklist not used (1·39 [1·02–1·90], p=0·035), and ventilation or parenteral nutrition unavailable when needed (ventilation 1·96, [1·41–2·71], p=0·0001; parenteral nutrition 1·35, [1·05–1·74], p=0·018). Administration of parenteral nutrition (0·61, [0·47–0·79], p=0·0002) and use of a peripherally inserted central catheter (0·65 [0·50–0·86], p=0·0024) or percutaneous central line (0·69 [0·48–1·00], p=0·049) were associated with lower mortality. Interpretation Unacceptable differences in mortality exist for gastrointestinal congenital anomalies between lowincome, middle-income, and high-income countries. Improving access to quality neonatal surgical care in LMICs will be vital to achieve Sustainable Development Goal 3.2 of ending preventable deaths in neonates and children younger than 5 years by 2030
    corecore